I’ll quickly show here the procedure for replacing a Physical Disk in predictive failure status in the Storage Cell.

Check which disk is failed:
CellCLI> LIST PHYSICALDISK
CellCLI> LIST PHYSICALDISK PLMU9V DETAIL
name: 8:6
deviceId: 11
deviceName: /dev/sdg
diskType: HardDisk
enclosureDeviceId: 8
errOtherCount: 0
luns: 0_6
makeModel: "HGST H7280A520SUN8.0T"
physicalFirmware: P901
physicalInsertTime: 2016-06-28T16:39:08-03:00
physicalInterface: sas
physicalSerial: PLMU9V
physicalSize: 7.153663907200098T
slotNumber: 6
status: warning - predictive failure
List the LUN to see more details and make sure that is not used for Cell OS:
CellCLI> list lun 0_6 detail
name: 0_6
deviceName: /dev/sdg
diskType: HardDisk
id: 0_6
isSystemLun: FALSE
lunSize: 7.152265548706055T
lunUID: 0_6
physicalDrives: 8:6
raidLevel: 0
lunWriteCacheMode: "WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU"
status: warning - predictive failure
Check if there is any griddisk that cannot be deactivated. If any griddisk is listed then you cannot proceed before fixing the issues that are preventing the griddisks to become inactive.
CellCLI> list griddisk attributes name, asmdeactivationoutcome
List the disk again before the replacement:
CellCLI> LIST PHYSICALDISK PLMU9V
8:6 PLMU9V warning - predictive failure
Drop the physical disk for replacement and then inform the Field Engineer onsite that he is ok to proceed with replacing the disk in the storage server:
CellCLI> ALTER PHYSICALDISK 8:6 DROP FOR REPLACEMENT
Physical disk 8:6 was dropped for replacement.
CellCLI> LIST PHYSICALDISK PLMU9V
8:6 PLMU9V warning - predictive failure - dropped for replacement
Oracle Field Engineer removes the physical disk from the disk slot:
CellCLI> LIST PHYSICALDISK PLMU9V
8:6 PLMU9V not present
The Field Engineer inserts the new disk into the slot and you are not able to see the disk by its previous serial number anymore:
CellCLI> LIST PHYSICALDISK PLMU9V;
CELL-02006: Physical disk does not exist: PLMU9V. Please use 'LIST PHYSICALDISK' to see valid disk names.
You can query using the enclosure and slot numbers which makes the name of the disk:
CellCLI> LIST PHYSICALDISK 8:6
8:6 PXG2ZV normal
Happy disk replacement.
Franky